PD6600 Loop Leader Loop-Powered Process Meter
Manufacturer: Precision DigitalPD6600 Loop Leader Loop-Powered Process Meter
Manufacturer: Precision DigitalThese loop-powered 1/8 DIN digital panel meters can be installed virtually anywhere to provide convenient and informative display of any 4-20 mA signal.
One of the most convenient features of these instruments is their dual line display, which is typically used to display the process variable on the 5-digit alphanumeric top display and the units of measure or a tag on the 8-digit alphanumeric bottom display. Feet and inches models display level in feet and inches on the top display while the 8-digit alphanumeric bottom line may be used to display a tag or custom message.
Further enhancing the display on these instruments is a 20-segment bargraph available on the PD6603 and PD6604 that also includes a numeric value of the percentage the bargraph represents.
Free, PC-based, MeterView XL software that connects to the meter via a micro USB cable is available for programming and setup of the meters. All models come equipped with two open collector outputs and a digital input. There are also models available with two solid-state relays and isolated 4-20 mA analog output options.
The open collector outputs are useful for alarm indication. The digital input can be used to acknowledge the relays, to start/stop a timer/stopwatch, and more. The relays can be programmed for alarm indication, on/off control, or pump alternation.
- 1/8 DIN Loop-Powered Process Meters with NEMA 4X, IP65 Front
- 4-20 mA Input Displayed with ±0.02% FS Accuracy
- 1.5 Volt Drop (4.5 Volt Drop with Backlight)
- 0.7" (17.8 mm) 5 Digits 7-Segment, FT-IN & Fractions, Top Display (PD6603)
- 0.7" (17.8 mm) 5 Alphanumeric Characters Top Display (PD6602/4)
- 0.4" (10.2 mm) 8 Alphanumeric Characters Bottom Display
- Displays Level in Feet & Inches up to 999 Feet, 11 & 15/16 Inches (PD6603)
- 20-Segment Bargraph with Numeric Percent Indication, Optional
- (2) Open Collector Outputs Standard; Assignable to Pulse, Alarm, Timer, or Stopwatch
- (2) Optional Loop-Powered Solid-State Relays; Assignable to Alarm, Control, Timer, or Stopwatch
- Stopwatch & Timer Functions to Drive Relays & Open Collectors
- Optional Isolated 4-20 mA Analog Output
- Relay Pump Alternation Based on Level and Runtime
- Display Relay Runtime & Cycle Count via Relay Info Menu
- Round Horizontal Tank Function; Just Enter Diameter & Length
- 32-Point Linearization, Square Root Extraction and Programmable Exponent Function
- Free PC-Based MeterView XL USB Programming Software
- Loop-Powered Backlight with Red Backlight for Alarm Conditions
- Operating Temperature Range: -40 to 167°F (-40 to 75°C)
- Conformal Coated PCBs for Dust & Humidity Protection
- 3-Year Warranty
Specifications
Manufacturer
Display
- Dual-line LCD with backlight
- PD6602/4: Both lines 14-segment alphanumeric
- PD6602/4: Top: 0.7" (17.8 mm) 5 digits
- PD6603: Top: 0.7" (17.8 mm), 5 digits 7-segment, FT-IN & fractions
- PD6602/4: Bottom: 0.4" (10.2 mm) 8 characters
- PD6603: Bottom: 0.4" (10.2 mm), 8 alphanumeric 14-segment characters
- Display may be programmed to turn red and flash a user-defined message on alarm condition
Alarm Indication
- Programmable: red backlight, flashing display, alarm symbol (!) (not available on bargraph models), bargraph segment flashes on alarm
Programming Method
- Front panel & Free PC-based USB programming software
Enclosure & Material
- Enclosure: 1/8 DIN, IP65, NEMA 4X front panel, high impact plastic, NORYL® polyphenylene ether & polystyrene blend (PPE PS) resin, UL 94V-0
- Color: gray
- Gasket: Silicone Rubber
- aceplate: LEXAN® polycarbonate (PC) Film
- Buttons: Silicone rubber
Environmental
- Operating: -40 to 75°C (-40 to 167°F)
- Storage: -40 to 85°C (-40 to 185°F)
- Relative humidity: 0 to 90% non-condensing
- Printed circuit boards are conformally coated
Noise Filter
- Averages the input signal over a period of time between 1 and 16 seconds to dampen the effects of a noisy signal that causes a jumpy display
Filter Bypass
- 0.0 to 99.9% of full scale. Input signal changes greater than bypass value are displayed immediately
Recalibration
- Recalibration is recommended at least every 12 months
Max/Min Display
- Max/min readings reached by the process are stored until reset by the user or until power to the meter is turned off
Tare
- Tare function zeros out the meter to accommodate for weight of a container
- Tare function can be assigned to a function key or a digital input
Normal Mode Rejection
- 64 dB at 50/60 Hz
Connections
- Removable screw terminals accept 12 to 22 AWG wire
Tightening Torque
- Screw terminal connectors: 4.5 lb-in (0.5 Nm)
- Mounting screws: 8.0 lb-in max. (0.9 Nm)
Overall Dimensions
- 4.68" x 2.45" x 3.79" (119 mm x 62 mm x 96 mm) (W x H x D)
Weight
- 8.7 oz (247 g) with option board
Input
- 4-20 mA
Accuracy
- ±0.02% of span ±1 count
- PD6602/4: Square root and programmable exponent: 10-100% FS
Power Supply
- External Loop: 7.0 VDC to 30.0 VDC maximum
Resistance
- Output Loop: 10-750 Ω @ 24 VDC; 10-1100 Ω @ 30 VDC
Environmental Protection
- IP65
- NEMA 4X