The XTP601 Oxygen Analyzer for safe or hazardous areas is a robust, linear and stable device that is used for measurements in gases such as biogas, methane, hydrogen, nitrogen or carbon dioxide. The analyzer meets the requirements of IEC61508 SIL2. 
 
A robust, linear and stable oxygen analyzer for measurements in gases such as hydrogen, nitrogen, methane, biogas, or carbon dioxide. 
 
The analyzer is housed in an IP66 rugged casing, making it suitable for a wide range of applications. 
 
The XTP601 can be supplied with flame arrestors, as either explosion-proof and certified for use in hazardous areas or for use with flammable gases in a safe area.
Features
  • General purpose or ATEX, UKCA, IECEx, cQPSus, TR CU & Ex hazardous area certified models
  • SIL2 Capable
  • Ranges available: 0...0.5 % up to 0...50 % & 20, 80 or 90...100 %
  • Touch-screen display allows calibration or adjustment without the need for a hot works permit
  • Intrinsic error (accuracy) is better than 1 % full scale
  • Zero range stability better than 0.25 % of range per month
  • Outputs include RS485 and two 4...20 mA (following NAMUR NE 44 standard)
  • Low cost of ownership due to minimal maintenance and no consumable parts

Specifications

Approvals & Certifications

  • ATEX/UKCA
  • IECEx
  • cQPSus
  • TR CU Ex

Measurement Range

  • 0-0.5 % to 0-50 %
  • 20-100 % to 90-100%

Accuracy

  • Better than ±1 % full scale (±0.2 % O2 between 80 and 100 %)

Ingress Protection

  • IP55
  • IP66, NEMA 4X

Display Resolution

  • 0.01 %; 0.1 % for suppressed zero ranges

Display Type

  • Backlit LCD (not on 501-GP2 model)

Repeatability

  • ±0.2 % of range or ±0.02 % O2, whichever is greater

Linearity

  • ±0.5 % of range or ±0.05 % O2, whichever is greater

Sample Flow Rate

  • General Purpose: 100 to 500 ml/min (0.25 to 1.0 scfh)
  • Ex Version: 270 to 330 ml/min (0.57 to 0.7 scfh)

Analog Input

  • 1 off mA input for an external sensor (can be displayed on the screen)
  • 1 off mA input to act as an active compensation for the process conditions

Analog output

  • 2 off 4-20 mA outputs (powered with 24V excitation voltage)

Power Supply

  • 24 VDC, 1.6 A max

Ambient Temperature

  • 5° to 60° C (41° to 140° F)

Wetted Material

  • 316L stainless steel, borosilicate glass, platinum (plus O-ring)

O-ring

  • Viton, Silicone or Ekraz

Gas Connection

  • 1/4" NPT Female (GP1)
  • 1/8” NPT Female (Ex & GP2)
  • 1/8" bulkhead standard

  • Monitoring Inert Blanketing Gases for Hydrocarbon Processing
  • Inert Gas for Pharmaceutical or Chemical Industries
  • Biogas, Waste, Landfill and Digester Plants
  • Furnace Gas Control in Steel Industry
  • N2 Generators
  • O2 Generators