PS200 Portable Gas Detector
Manufacturer: Teledyne| DetconPS200 Portable Gas Detector
Manufacturer: Teledyne| DetconThe PS200 Series detects all possible combinations of LEL, O2, CO, H2S, including single gas detection.
In addition to displaying all gas readings simultaneously, the user can also initiate a manual bump test anytime.
The PS200 accessory pack includes the following as standard: USB Charging / Comms Clip, Universal Power Plug, User CD-ROM, Quick Operating Instructions.
Tubing (3 m) complete with a Quick Connector is also supplied as standard with pumped instruments.
Features- Simple 1-Button Operation
- Any combination of (LEL/O2/CO/H2S)
- Audible, Visual and Vibrating Alarms
- Fully Certified
- Internal Pump (Optional)
- Lightweight
- Sensor Integrity Checking
- Robust Construction
- Ease of Maintenance
Specifications
Manufacturer
Alarm
- Highly Visible Flashing LED, Piercing > 90 dB Audible
Approvals & Certifications
- ATEX Ex II 2 G Ex ia D IIC T4
- CE 0518
- CSA Class I, Div. 2, Grade A, B, C, D, T4
- CSA Class I, Zone 1, EX Ia D IIC, T4
- IEC 60079-29-1
- IEC Ex ia D IIC T4 Gb
- MED (0038/YY) - Module B & E
Battery Life
- < 4 Hours - Charging Time
- 0 to 14 Hours - Run Time
Communication
- Data Logging
- Standalone
- USB
Display
- LCD Display (Green & Red)
Enclosure, Body Material
- High Impact Rubberized Polycarbonate Case
Environmental Protection
- IP67
Humidity
- 0 to 95 % Relative Humidity, Non-Condensing
Indication
- LED - Power (Green), Testing (Yellow), Pass (Green), Fail (Red)
Measuring Range
- 0 to 1,000 ppm CO
- 0 to 100 ppm H₂S
- 0 to 100 % Lower Explosive Limit (LEL)
- 0 to 25 % O₂
Media
- Gas
Port
- 3-Port - Gas
Power Requirement
- 12 Vdc, 2 A
- Lithium Ion Rechargeable Battery
Response Time
- 10 to 20 seconds (T90)
- 60 seconds - Bump Testing Time
- 90 seconds - Calibration Testing Time
Sensor, Probe Type
- Catalytic Bead
- Electrochemical
Temperature Range
- -20° to 50° C (-4° to 122° F)