Price
Request a Quote
Stock
In Stock

  • Power Type - Output Loop Powered
  • Loop Output - With
  • Options - Isolated Signal 2-Wire RS-485 with Modbus Protocol

Specifications

Manufacturer

Approvals & Certifications

  • ATEX II 2 GD Ex d IIC T6 Gb Ex Tb IIIC T85° C Db IP68 Ta = -40° to 75° C
  • CSA Class I, Div. 1, Groups B, C, D, Class II, Div. 1, Groups E, F, G Class III, Div. 1, T6 Class I, Zone 1, Ex d IIC T6 Ta = -40° to 75° C
  • FM Explosion-proof for use in Class I, Div. 1, Groups B, C, D, Class II, Div. 1, Groups E, F, G, Class III, Div. 1, T6. Class I, Zone 1, AEx d IIC T6 Gb. Zone 21, AEx Tb IIIC T85° C. Ta = -40° to 75° C
  • IEC Ex Ex d IIC T6 Gb Ex Tb IIIC T85° C Db IP68 Ta = -40° to 75° C

Environmental Protection

  • IP66
  • IP68
  • NEMA 4X
  • NEMA 7
  • NEMA 9

Display

  • Top: Five Digits (0 to 99,999), 0.7” (17.8 mm) high, 7-segment, automatic Lead Zero Blanking. Bottom: Seven characters, 0.4” (10.2 mm) high, 14-segment automatic Lead Zero Blanking. Symbols: Total, grand total, battery Power/low battery, high & Low Alarm, password lock, and SafeTouch Button Sleep mode/disable.

Display Assignment

  • Top Display: Rate or total, Bottom Display: Combinations of rate, total, grand total, units, and custom tag.

Backlight

  • White LED, 10 sec auto-off when battery Powered. Backlight deactivated below Temperature ≈ -20° C

Display Update Rate

  • Ambient > -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient -20° C: 1 Update/Second. Ambient < -20° C: 1 Update/10 Seconds. Note: Update is dependent on gate settings.

Display Orientation

  • Display may be Mounted at 90° increments up to 270° from default orientation

Overrange

  • Display flashes 99,999

Programming Method

  • Four SafeTouch through-glass buttons when cover is installed. Four internal push buttons when cover is removed.

Recalibration

  • Calibrated at the factory to Read frequency in Hz. No recalibration Required

Maximum / Minimum Display

  • Max./Min. Readings reached by the process are stored until reset by the user or until power to the meter is cycled.

Password Menu Options

  • Pass GT: Restricts the reset of grand total to Require re-entering the password. May enable a Non-Resettable grand total and permanent lockout of grand total-Related settings with a Specific password.
  • Pass T: Restricts the reset of total to Require re-entering the password. Disables the manual mode reset Contact.
  • Pass: Restricts modifications of programmed settings to Require re-entering the password to make changes.
  • Three Programmable password selections can be used for the following: Restrict modification of settings, prevent resetting the total or grand total without the password, or permanently lock out the ability to change or reset the grand total or any grand total Related settings (making a Non-Resettable grand total).

Alarm Indication

  • Flashing display plus HI/LO indicators for rate Alarms, SET for total Alarms

Non-Volatile Memory

  • All programmed settings and total are stored in non-volatile memory for a minimum of ten years if power is lost.

Battery

  • 3.6 V Primary Lithium (Li-SOCl2), Non-Rechargeable Model PDABAT36C. Expected Service life & recommended replacement interval is dependant on the Operating conditions.

Power Options

  • 9-30 Vdc, 2.2 W max, 4-20 mA Output Powered, 30 Vdc max, battery Power, 9-30 Vdc Power with battery backup, 4-20 mA Output Powered with Battery Backup.

Isolation

  • Note: Requires separate output Supply
  • PD6830-BTA: 500 V Input-to-output.
  • PD6830-BMA: 500 V Input/power-to-output
  • PD6830-APA: 500 V Input/power-to-output
  • All models: 500 V opto-Isolated Input-to-Power/output with isolated Input enabled.

Data Logging

  • Up to 1024 records, recorded 4/day at Specific times or at defined time intervals. Record Contains date, time, rate, total, grand total, and log number.

Operating Temperature Range

  • -40° to 75° C

Storage Temperature Range

  • -40° to 75° C

Relative Humidity

  • 0 to 90 % Non-Condensing

Connections

  • Screw terminals accept 12 to 22 AWG wire

Enclosure

  • Explosion-proof die-Cast Aluminum with glass Window, corrosion resistant epoxy Coating, color: Blue. NEMA 4X IP68. Copper-Free (0.3 %). Three 3/4” NPT threaded conduit openings. One 3/4” NPT metal plug with 12 mm hex key Fitting installed.

Mounting

  • May be mounted directly to conduit. Two slotted flanges for wall mounting or NPS 1-1/2” to 2-1/2” or DN 40 to 65 mm pipe mounting.

Overall Dimensions

  • 5.67” x 5.24” x 4.88” (W x H x D)(144 mm x 133 mm x 124 mm)

Weight

  • 5.00 lbs (80 oz., 2.27 kg)

Warranty

  • 3 Years Parts and Labor
show more